Frer Analog Meters

TECHNICAL DETAILS

  • Accuracy 1.5%
  • Operating temperature -25 +50°C
  • Protection for housing IP52
  • Manufactured according to CEI-DIN-VDE-IEC

OPTIONS

  • Vibration proof version
  • Ship mounting
  • Class 1% calibration
  • Red reference mark
  • Antiglare glass
  • Scale with double or triple numbering

90 Degrees Scale Analog Meters

48 x 4872 x 7296×96144 x 144
AC Ammeter, x/5A, upto 100A directF48EAF72EAF96EAF14EA
AC Voltmeter, x/100-110V, upto 600V directF48EVF72EVF96EVF14EV
Frequency Meter, Input: 57.7-440VF48FPF72FPF96FPF14FP
Power Factor Meter, 3p, 3w system 0.5-1-0.5. Input: 1A or 5A, 100V-440VF48PYF72PYF96PYF14PY
Wattmeter, Input: 1A or 5A, 100V-440V, 3p, 3w. with separate accessory transducerF48WDF72WDF96WDF14WD
Wattmeter, Input: 1A or 5A, 100V-440V, 3p, 4w. with separate accessory transducerF48WTF72WTF96WTF14WT
VAR meter, Input: 1A or 5A, 100V-440V, 3p, 3w. with separate accessory transducerF48RDF72RDF96RDF14RD
VAR meter, Input: 1A or 5A, 100V-440V, 3p, 4w. with separate accessory transducerF48RTF72RTF96RTF14RT
DC Ammeter, Shunt OperatedF48MAF72MAF96MAF14MA
DC Voltmeter (to 600V)F48MVF72MVF96MVF14MV

240 Degrees Scale Analog Meters

48 x 4872 x 7296×96144 x 144
AC Ammeter, x/5A, upto 100A directA48EAA72EAA96EAA14EA
AC Voltmeter, x/100-110V, upto 600V directA48EVA72EVA96EVA14EV
Frequency Meter, Input: 57.7-440VA48FPA72FPA96FPA14FP
Power Factor Meter, 3p, 3w system 0.5-1-0.5. Input: 1A or 5A, 100V-440VA48PYA72PYA96PYA14PY
Wattmeter, Input: 1A or 5A, 100V-440V, 3p, 3w. with separate accessory transducerA48WDA72WDA96WDA14WD
Wattmeter, Input: 1A or 5A, 100V-440V, 3p, 4w. with separate accessory transducerA48WTA72WTA96WTA14WT
VAR meter, Input: 1A or 5A, 100V-440V, 3p, 3w. with separate accessory transducerA48RDA72RDA96RDA14RD
VAR meter, Input: 1A or 5A, 100V-440V, 3p, 4w. with separate accessory transducerA48RTA72RTA96RTA14RT
DC Ammeter, Shunt OperatedA48MAA72MAA96MAA14MA
DC Voltmeter (to 600V)A48MVA72MVA96MVA14MV
360° 4 Quadrants Power-Factor Meter, 3p, 4w system 0-1-0. Input: 1A or 5A, 100V-440VA96PTL

Synchronizing Instruments

96×96144 x 144
Double Voltmeter Coaxial type, 100-440VF96YVF14YV
Double Voltmeters Opposite pointer type, 100-440VF96YVEF14YVE
Double Frequency meters Coaxial type, Input: 57.7-440VF96YFF14YF
Double Frequency meters Opposite pointer type, Input: 57.7-440VF96YFEF14YFE
LED Synchroscope, Flashing Green LED, Input: 100-440VF96YSDF14YSD
Checking Synchroscopes, Relay Contact 5A/220V, Input: 100-440VF96YSCF96YSC
Differential Voltmeter, +/-20% or +/-10%A96YVDA14YVD
Differential Frequencymeters, +/-20% or +/-10%A96YFDA14YFD
Lamp synchroscopesF96YSLF14YSL
Null Voltmeters, 100-600VF96YZVF14YZV

Shunts

Voltage Drop60mV, 100mV, 150mV
Primary Current1A to 15,000A
Accuracy0.5%