Cabur Terminal Blocks
Cabur Terminals with UL94V-0 polyamide insulating body, universal mounting onto both PR/DIN and PR/3 type rails – according to IEC 60715 Std., “G32” and “TH/35” types CESI 01 ATEX 090 U Ex e certificate I M2 / II 2 G D operating temperature range –40 ÷ +80 °C. Available in standard (beige RAL 1001 colour) or (Ex)i “intrinsic safety” circuits (blue RAL 5015 colour) versions
| CBD.2 | CBD.4 | CBD.6 | CBD.10 | CBD.16 | CBD.35 | CBD.50 |
Flexible/ Rigid Conductors | 0.5 to 4 mm2 | 0.5 to 6 mm2 | 0.5 to 10 mm2 | 0.5 to 16 mm2 | 0.5 to 25 mm2 | 0.5 to 35/50mm2 | 1.5 to 50/70mm2 |
Rated Current | 24 A | 32 A | 41 A | 57 A | 76 A | 125 A | 150 A |
Length x Height x Thickness (mm) | 40.5x47x5.5 | 44x52x6.5 | 44x52x8 | 44x55x10 | 47x57x12 | 52x60x16 | 57x62x18 |
End Section | CB2/PT | CB4/6/PT | CB4/6/PT | CB10/PT | CB16/PT | CB35/PT | CB50/PT |
Multiple Commoning Bar | PMP/01 | PMP/42 | PMP/13 | PMP/04 | PMP/05 | PMP/06 | PMP/07 |
Screw and Sleeve | CPM/21 | CPM/12 | CPM/83 | CPM/03 | CPM/44 | CPM/06 | CPM/07 |
| CT SHORTING DISCONNECT BY SLIDE LINK | FUSE / DIODE HOLDER TERMINAL | FUSE / DIODE HOLDER TERMINAL | DISCONNECT TERMINAL- | EARTH TERMINAL | EARTH TERMINAL | EARTH TERMINAL |
| SCB.6 | SFR.4 | SFR.6 | MPS.4 | TE.6 | TE.10 | TE.16 |
Flexible/ Rigid Conductors | 0.5 to 10 mm2 | 0.2 to 6 mm2 | 0.2 to 10 mm2 | 0.2 to 6 mm2 | 0.5 to 10mm2 | 0.5 to 16mm2 | 0.5 to 25mm2 |
Rated Current | 41 A | 6.3 A max. | 10 A max. | 24 A | – | – | – |
Length x Height x Thickness (mm) | 69x65x8 | 52x52x8 | 52x52x8 | 47x47x6 | 52x47x8 | 55x47x10 | 56x47x12 |
End Section | SCB/6/PT | SFR/PT | SFR.6/PT | MPS.4/PT | – | – | – |
Permanent cross-connection between two adjoining terminal blocks | POF/57 | – | – | – | – | – | – |
Switchable cross-connection between two adjoining terminal blocks | SCB/6/PO/2 SCB/6/PO/4 | – | – | – | – | – | – |
Multiple Commoning Bar | PMP/13 | – | – | – | – | – | – |
Screw and Sleeve | SCB/6/CPM | – | – | – | – | – | – |
Specific Accessories | SCB/6/CPM | LED / Diode | LED / Diode | – | – | – | – |
| DOUBLE LEVEL | UPPER DIS- CONNECT LEVEL | THREE LEVEL | TWO LEVEL + EARTH | FOR PROXIMITY SENSORS | FOR THERMOCOU- PLE CIRCUITS | FOR BLADE FUSE CAR- TRIDGE |
| DAS.4 | DSS.4 | TLD.2 | TDE.2 | TLS.2 | TC/PO | MPFA.4 |
Flexible/ Rigid Conductors | 0.2 to 6 mm2 | 0.2 to 6 mm2 | 0.2 to 4 mm2 | 0.2 to 4 mm2 | 0.2 to 4 mm2 | Ø 0.8 ÷ 1.3 mm | 0.2 to 6 mm2 |
Rated Current | 32 A | 32 inf / 24 sup | 24 A | 24 A | 24 A | thermocouple | 15 A max. |
Length x Height x Thickness (mm) | 64x62x6 | 78x66x6 | 85x52x6.2 | 82.5x52x6.2 | 62.5x52x6.2 | 40.5x47x5.5 | 47x47x6 |
End Section | DAS/PT | DSS/PT | TLD/PT | TLD/PT | TLS/PT | CB2/PT | MPS.4/PT |
Multiple Commoning Bar | PMP/58 | – | PMP/02 | PMP/02 | PMP/02 | – | – |
Screw and Sleeve | CPM/01 | – | CPM/01 | CPM/01 | CPM/01 | – | – |
| GPA.70 | GPA.95 | GPA.150 | GPA.240 | GPM.95/CC | GPM.150/CC | GPM.240/CC |
Flexible/ Rigid Conductors | 10 to 95 mm2 | 10 to 120 mm2 | 50 to 150 mm2 | 95 to 240 mm2 | 35 to 120 mm2 | 50 to 185 mm2 | 95 to 300 mm2 |
Rated Current | 192 A | 232 A | 309 A | 415 A | 269 A | 353 A | 452 A |
Length x Height x Thickness (mm) | 70x91x20.5 | 87x98x26 | 99x108x31 | 120x119x37 | 113x140x32 | 134x140x42 | 150x154x52 |
End Section | – | – | – | – | – | – | – |
Multiple Commoning Bar | PMP/08 | – | – | – | – | – | – |
Screw and Sleeve | CPM/70 | – | – | – | – | – | – |